{"id":74,"date":"2022-04-08T18:02:31","date_gmt":"2022-04-08T09:02:31","guid":{"rendered":"https:\/\/web-manual.dit-daikin.com\/ra\/3P649406-16\/?page_id=74"},"modified":"2022-04-08T18:02:31","modified_gmt":"2022-04-08T09:02:31","slug":"intelligent","status":"publish","type":"page","link":"https:\/\/web-manual.dit-daikin.com\/ra\/3P649406-16\/en\/intelligent\/","title":{"rendered":"INTELLIGENT EYE operation"},"content":{"rendered":"<div class=\"content_wrap\">\n<dl class=\"tit_page tit_ico\">\n<dt><img src=\"https:\/\/web-manual.dit-daikin.com\/ra\/3P649406-16\/wp-content\/themes\/1st_manual\/images\/common\/ico_ieo.gif\" alt=\"INTELLIGENT EYE operation\" \/><\/dt>\n<dd>\n<h2>INTELLIGENT EYE operation<\/h2>\n<\/dd>\n<\/dl>\n<section>\n<div class=\"container img_intelligent01 txt_c\">\n\t\t\t<img src=\"https:\/\/web-manual.dit-daikin.com\/ra\/3P649406-16\/wp-content\/themes\/1st_manual\/images\/functions\/img_intelligent01.gif\" alt=\"INTELLIGENT EYE operation\" \/>\n\t\t<\/div>\n<div class=\"container\">\n\t\t\tThe INTELLIGENT EYE sensor detects human movement and adjusts the right and left airflow direction. It can be set to avoid people or to direct airflow specifically at people.<br \/>\n\t\t\tIf no one is in the room for more than 20 minute, the operation automatically changes to energy saving operation.\n\t\t<\/div>\n<\/section>\n<section class=\"accordion_area\">\n<div class=\"box_accordion\">\n<div class=\"tit_accordion\">\n<div class=\"tit_accordion_box\">\n\t\t\t\t\tTo start\n\t\t\t\t<\/div>\n<div class=\"a_ico_box\"><span class=\"a_ico\"><\/span><\/div>\n<\/p><\/div>\n<div class=\"txt_accordion\">\n<div class=\"container\">\n<div class=\"att_accordion att_caution\">\n<div class=\"tit_att_accordion open\">\n<div class=\"tit_att_accordion_box\">\n\t\t\t\t\t\t\t\t<img src=\"https:\/\/web-manual.dit-daikin.com\/ra\/3P649406-16\/wp-content\/themes\/1st_manual\/images\/common\/ico_att02.png\" alt=\"CAUTION\" \/>CAUTION\n\t\t\t\t\t\t\t<\/div>\n<div class=\"at_ico_box\"><span class=\"at_ico\"><\/span><\/div>\n<\/p><\/div>\n<div class=\"txt_att_accordion att_active\">\n<ul class=\"dot_li case\">\n<li>\n\t\t\t\t\t\t\t\t\tDo not place large objects near the INTELLIGENT EYE sensor. Also keep heating units and humidifiers outside the sensor\u2019s detection area. This sensor can detect undesirable objects.\n\t\t\t\t\t\t\t\t<\/li>\n<li>\n\t\t\t\t\t\t\t\t\tDo not hit or violently push the INTELLIGENT EYE sensor. This can lead to damage and malfunction.\n\t\t\t\t\t\t\t\t<\/li>\n<\/ul><\/div>\n<\/p><\/div>\n<\/p><\/div>\n<div class=\"container\">\n<dl class=\"tit_square t_in\">\n<dt>\n<div class=\"square_box\"><\/div>\n<\/dt>\n<dd>\n<h3>Press <img class=\"ico_b_sensor\" src=\"https:\/\/web-manual.dit-daikin.com\/ra\/3P649406-16\/wp-content\/themes\/1st_manual\/images\/common\/ico_b_sensor.svg\" alt=\"sensor\" \/> and select the desired mode.<\/h3>\n<\/dd>\n<\/dl>\n<div class=\"tit_square_box\">\n<ul class=\"dot_li case\">\n<li>\n\t\t\t\t\t\t\t\tEach time <img class=\"ico_b_sensor_mi\" src=\"https:\/\/web-manual.dit-daikin.com\/ra\/3P649406-16\/wp-content\/themes\/1st_manual\/images\/common\/ico_b_sensor.svg\" alt=\"sensor\" \/> is pressed, a different setting option appears on the LCD.<\/p>\n<div class=\"img_intelligent02 txt_c\">\n\t\t\t\t\t\t\t\t\t<img src=\"https:\/\/web-manual.dit-daikin.com\/ra\/3P649406-16\/wp-content\/themes\/1st_manual\/images\/functions\/img_intelligent02.gif\" alt=\"INTELLIGENT EYE operation\" \/>\n\t\t\t\t\t\t\t\t<\/div>\n<\/li>\n<li>When the louvres (vertical blades) are swinging, selecting any of the modes above will cause the louvres (vertical blades) to stop.<\/li>\n<li>The horizontal airflow direction is set to \u201cAUTO\u201d. The INTELLIGENT EYE sensor detects people on the left side, right side, and in front.<\/li>\n<\/ul><\/div>\n<\/p><\/div>\n<div class=\"container\">\n<div class=\"att_accordion att_note\">\n<div class=\"tit_att_accordion open\">\n<div class=\"tit_att_accordion_box\">\n\t\t\t\t\t\t\t\tNOTE\n\t\t\t\t\t\t\t<\/div>\n<div class=\"at_ico_box\"><span class=\"at_ico\"><\/span><\/div>\n<\/p><\/div>\n<div class=\"txt_att_accordion att_active\">\n<h3 class=\"tit_bold\">Notes on combining INTELLIGENT EYE operation and CEILING AIRFLOW operation<\/h3>\n<ul class=\"dot_li case\">\n<li>\n\t\t\t\t\t\t\t\t\tINTELLIGENT EYE operation can operate in combination with CEILING AIRFLOW operation.<br \/>\n\t\t\t\t\t\t\t\t\tWhen the INTELLIGENT EYE operation is set to blow directly on people and CEILING AIRFLOW operation is activated simultaneously, the air conditioner tracks you horizontally, without the air blowing directly on you.\n\t\t\t\t\t\t\t\t<\/li>\n<li>\n\t\t\t\t\t\t\t\t\tThe airflow rate will be set to AUTO. If the up and down airflow direction is selected, the CEILING AIRFLOW operation will be canceled. Priority is given to the function of whichever button is pressed last.\n\t\t\t\t\t\t\t\t<\/li>\n<\/ul><\/div>\n<\/p><\/div>\n<\/p><\/div>\n<div class=\"btn_close\">Close<\/div>\n<\/p><\/div>\n<\/p><\/div>\n<div class=\"box_accordion\">\n<div class=\"tit_accordion\">\n<div class=\"tit_accordion_box\">\n\t\t\t\t\tTo cancel\n\t\t\t\t<\/div>\n<div class=\"a_ico_box\"><span class=\"a_ico\"><\/span><\/div>\n<\/p><\/div>\n<div class=\"txt_accordion\">\n<div class=\"container\">\n<dl class=\"tit_square t_in\">\n<dt>\n<div class=\"square_box\"><\/div>\n<\/dt>\n<dd>\n<h3>Press <img class=\"ico_b_sensor\" src=\"https:\/\/web-manual.dit-daikin.com\/ra\/3P649406-16\/wp-content\/themes\/1st_manual\/images\/common\/ico_b_sensor.svg\" alt=\"sensor\" \/> until no icon is displayed.<\/h3>\n<\/dd>\n<\/dl><\/div>\n<div class=\"btn_close\">Close<\/div>\n<\/p><\/div>\n<\/p><\/div>\n<div class=\"box_accordion\">\n<div class=\"tit_accordion\">\n<div class=\"tit_accordion_box\">\n\t\t\t\t\tHow INTELLIGENT EYE operation works\n\t\t\t\t<\/div>\n<div class=\"a_ico_box\"><span class=\"a_ico\"><\/span><\/div>\n<\/p><\/div>\n<div class=\"txt_accordion\">\n<div class=\"container\">\n<div class=\"case\">\n\t\t\t\t\t\tIf no one is in the room for more than 20 minutes, the operation automatically changes to energy saving operation.<br \/>\n\t\t\t\t\t\tThe INTELLIGENT EYE sensor works differently depending on the situation.\n\t\t\t\t\t<\/div>\n<div class=\"case\">\n<h3 class=\"tit_bold\">[Example]<\/h3>\n<table class=\"tb_style tb_intelligent\">\n<tr>\n<td class=\"tb_intelligent_td_img tb_intelligent_img01\"><img src=\"https:\/\/web-manual.dit-daikin.com\/ra\/3P649406-16\/wp-content\/themes\/1st_manual\/images\/functions\/img_intelligent03.png\" alt=\"\" \/><\/td>\n<td class=\"tb_intelligent_td_img tb_intelligent_img01\"><img src=\"https:\/\/web-manual.dit-daikin.com\/ra\/3P649406-16\/wp-content\/themes\/1st_manual\/images\/functions\/img_intelligent04.png\" alt=\"\" \/><\/td>\n<\/tr>\n<tr>\n<th colspan=\"2\">A person is detected in area 1.<\/th>\n<\/tr>\n<tr>\n<td class=\"tb_intelligent_td_img\"><img src=\"https:\/\/web-manual.dit-daikin.com\/ra\/3P649406-16\/wp-content\/themes\/1st_manual\/images\/functions\/img_intelligent05.gif\" alt=\"A person is detected in area 1.\" \/><\/td>\n<td class=\"tb_intelligent_td_img\"><img src=\"https:\/\/web-manual.dit-daikin.com\/ra\/3P649406-16\/wp-content\/themes\/1st_manual\/images\/functions\/img_intelligent06.gif\" alt=\"A person is detected in area 1.\" \/><\/td>\n<\/tr>\n<tr>\n<th colspan=\"2\">A person is detected in area 2.<\/th>\n<\/tr>\n<tr>\n<td class=\"tb_intelligent_td_img\"><img src=\"https:\/\/web-manual.dit-daikin.com\/ra\/3P649406-16\/wp-content\/themes\/1st_manual\/images\/functions\/img_intelligent07.gif\" alt=\"A person is detected in area 2.\" \/><\/td>\n<td class=\"tb_intelligent_td_img\"><img src=\"https:\/\/web-manual.dit-daikin.com\/ra\/3P649406-16\/wp-content\/themes\/1st_manual\/images\/functions\/img_intelligent08.gif\" alt=\"A person is detected in area 2.\" \/><\/td>\n<\/tr>\n<tr>\n<th colspan=\"2\">People are detected in both areas.<\/th>\n<\/tr>\n<tr>\n<td>\n<div class=\"tb_intelligent_img02\">\n\t\t\t\t\t\t\t\t\t\tThe airflow is directed to Area 1.\n\t\t\t\t\t\t\t\t\t<\/div>\n<p>\t\t\t\t\t\t\t\t\t<img src=\"https:\/\/web-manual.dit-daikin.com\/ra\/3P649406-16\/wp-content\/themes\/1st_manual\/images\/functions\/img_intelligent09.gif\" alt=\"The airflow is directed to Area 1.\" \/>\n\t\t\t\t\t\t\t\t<\/td>\n<td>The current airflow direction is maintained.<\/td>\n<\/tr>\n<tr>\n<th colspan=\"2\">No people are detected in the areas.<\/th>\n<\/tr>\n<tr>\n<td>\n\t\t\t\t\t\t\t\t\tThe air conditioner will switch to energy-saving mode after 20 minutes.\n\t\t\t\t\t\t\t\t<\/td>\n<td class=\"no_bl\"><img src=\"https:\/\/web-manual.dit-daikin.com\/ra\/3P649406-16\/wp-content\/themes\/1st_manual\/images\/functions\/img_intelligent10.gif\" alt=\"No people are detected in the areas.\" \/><\/td>\n<\/tr>\n<\/table>\n<p>\t\t\t\t\t\t* The airflow direction may differ from the illustrated direction depending on the actions and movements of the people in the areas.\n\t\t\t\t\t<\/p><\/div>\n<\/p><\/div>\n<div class=\"container\">\n<div class=\"att_accordion att_note\">\n<div class=\"tit_att_accordion open\">\n<div class=\"tit_att_accordion_box\">\n\t\t\t\t\t\t\t\tNOTE\n\t\t\t\t\t\t\t<\/div>\n<div class=\"at_ico_box\"><span class=\"at_ico\"><\/span><\/div>\n<\/p><\/div>\n<div class=\"txt_att_accordion att_active\">\n<h3 class=\"tit_bold\">Notes on INTELLIGENT EYE operation<\/h3>\n<ul class=\"dot_li case\">\n<li>\n\t\t\t\t\t\t\t\t\tApplication range is as follows.<\/p>\n<div class=\"img_intelligent_box\">\n<div class=\"img_intelligent11\">\n\t\t\t\t\t\t\t\t\t\t\t<img src=\"https:\/\/web-manual.dit-daikin.com\/ra\/3P649406-16\/wp-content\/themes\/1st_manual\/images\/functions\/img_intelligent11.gif\" alt=\"Vertical angle 90\" \/>\n\t\t\t\t\t\t\t\t\t\t<\/div>\n<div class=\"img_intelligent12\">\n\t\t\t\t\t\t\t\t\t\t\t<img src=\"https:\/\/web-manual.dit-daikin.com\/ra\/3P649406-16\/wp-content\/themes\/1st_manual\/images\/functions\/img_intelligent12.gif\" alt=\"Horizontal angle 110\" \/>\n\t\t\t\t\t\t\t\t\t\t<\/div>\n<\/p><\/div>\n<\/li>\n<li>\n\t\t\t\t\t\t\t\t\tWhen the air conditioner is function in INTELLIGENT EYE operation, if no people are detected in the areas for 20 minutes, the air conditioner switches to the energy-saving mode with the set temperature shifted by 2\u00b0C.<br \/>\n\t\t\t\t\t\t\t\t\tThe air conditioner may switch to the energy-saving operation even if there are people in the areas. It may happen depending on the clothes people are wearing if there are no movements of the people in the areas.\n\t\t\t\t\t\t\t\t<\/li>\n<li>\n\t\t\t\t\t\t\t\t\tThe airflow direction from the louvres will be leftward if there are people in both areas 1 and 2. The air will also flow left if there is a person right in front of the sensor as the sensor judges that there are people in both areas.\n\t\t\t\t\t\t\t\t<\/li>\n<li>\n\t\t\t\t\t\t\t\t\tDue to the position of the sensor, people might be exposed to the airflow of the indoor unit if they are close to the front side of the indoor unit. If there are people close to the front side of the indoor unit or in both areas, it is recommended to use the CEILING AIRFLOW and INTELLIGENT EYE operations simultaneously. Using both modes together, the air conditioner will not direct the airflow towards the people.\n\t\t\t\t\t\t\t\t<\/li>\n<li>\n\t\t\t\t\t\t\t\t\tThe sensor may not detect moving objects further than 5m away. (Please see the application range)\n\t\t\t\t\t\t\t\t<\/li>\n<li>\n\t\t\t\t\t\t\t\t\tSensor detection sensitivity changes according to the indoor unit location, the speed of passers-by, temperature range, etc.\n\t\t\t\t\t\t\t\t<\/li>\n<li>\n\t\t\t\t\t\t\t\t\tThe sensor could also mistakenly detect pets, sunlight, fluttering curtains and light reflected off of mirrors as passers-by.\n\t\t\t\t\t\t\t\t<\/li>\n<li>\n\t\t\t\t\t\t\t\t\tNIGHT SET mode will not switch on during use of INTELLIGENT EYE operation.<\/p>\n<div class=\"btn_detail\">\n\t\t\t\t\t\t\t\t\t\t<a target=\"_blank\" href=\"..\/timer24\/#acc-time24\" rel=\"noopener\">Details<\/a>\n\t\t\t\t\t\t\t\t\t<\/div>\n<\/li>\n<\/ul><\/div>\n<\/p><\/div>\n<\/p><\/div>\n<div class=\"btn_close\">Close<\/div>\n<\/p><\/div>\n<\/p><\/div>\n<div class=\"box_accordion\">\n<div class=\"tit_accordion\">\n<div class=\"tit_accordion_box\">\n\t\t\t\t\tINTELLIGENT EYE operation is useful for energy saving\n\t\t\t\t<\/div>\n<div class=\"a_ico_box\"><span class=\"a_ico\"><\/span><\/div>\n<\/p><\/div>\n<div class=\"txt_accordion\">\n<div class=\"container\">\n<h3 class=\"tit_bold\">Energy saving operation<\/h3>\n<ul class=\"dot_li case\">\n<li>\n\t\t\t\t\t\t\tIf no presence detected in the room for 20 minutes, the energy saving operation will start.\n\t\t\t\t\t\t<\/li>\n<li>\n\t\t\t\t\t\t\tThis operation changes the temperature by +2\u00b0C in COOL \/ +2\u00b0C in DRY operation from the set temperature. When the room temperature exceeds 30\u00b0C, the operation changes the temperature by +1\u00b0C in COOL \/ +1\u00b0C in DRY operation from the set temperature.\n\t\t\t\t\t\t<\/li>\n<li>\n\t\t\t\t\t\t\tThis operation decreases the airflow rate slightly in FAN operation only.\n\t\t\t\t\t\t<\/li>\n<\/ul><\/div>\n<div class=\"btn_close\">Close<\/div>\n<\/p><\/div>\n<\/p><\/div>\n<\/section>\n<\/div>\n","protected":false},"excerpt":{"rendered":"<p>INTELLIGENT EYE operation The INTELLIGENT EYE sensor detects human movement and adjusts the right and left air [&hellip;]<\/p>\n","protected":false},"author":1,"featured_media":0,"parent":203,"menu_order":0,"comment_status":"closed","ping_status":"closed","template":"page_functions.php","meta":[],"tags":[],"_links":{"self":[{"href":"https:\/\/web-manual.dit-daikin.com\/ra\/3P649406-16\/wp-json\/wp\/v2\/pages\/74"}],"collection":[{"href":"https:\/\/web-manual.dit-daikin.com\/ra\/3P649406-16\/wp-json\/wp\/v2\/pages"}],"about":[{"href":"https:\/\/web-manual.dit-daikin.com\/ra\/3P649406-16\/wp-json\/wp\/v2\/types\/page"}],"author":[{"embeddable":true,"href":"https:\/\/web-manual.dit-daikin.com\/ra\/3P649406-16\/wp-json\/wp\/v2\/users\/1"}],"replies":[{"embeddable":true,"href":"https:\/\/web-manual.dit-daikin.com\/ra\/3P649406-16\/wp-json\/wp\/v2\/comments?post=74"}],"version-history":[{"count":0,"href":"https:\/\/web-manual.dit-daikin.com\/ra\/3P649406-16\/wp-json\/wp\/v2\/pages\/74\/revisions"}],"up":[{"embeddable":true,"href":"https:\/\/web-manual.dit-daikin.com\/ra\/3P649406-16\/wp-json\/wp\/v2\/pages\/203"}],"wp:attachment":[{"href":"https:\/\/web-manual.dit-daikin.com\/ra\/3P649406-16\/wp-json\/wp\/v2\/media?parent=74"}],"wp:term":[{"taxonomy":"post_tag","embeddable":true,"href":"https:\/\/web-manual.dit-daikin.com\/ra\/3P649406-16\/wp-json\/wp\/v2\/tags?post=74"}],"curies":[{"name":"wp","href":"https:\/\/api.w.org\/{rel}","templated":true}]}}