{"id":35,"date":"2022-04-07T21:31:16","date_gmt":"2022-04-07T12:31:16","guid":{"rendered":"https:\/\/web-manual.dit-daikin.com\/ra\/3P658678-5\/?page_id=35"},"modified":"2022-10-20T00:34:32","modified_gmt":"2022-10-19T15:34:32","slug":"preparation","status":"publish","type":"page","link":"https:\/\/web-manual.dit-daikin.com\/ra\/3P658678-5\/en\/preparation\/","title":{"rendered":"Preparation before operation"},"content":{"rendered":"<div class=\"content_wrap\">\n<div class=\"tit_page\">\n<h2>Preparation before operation<\/h2>\n<\/p><\/div>\n<section class=\"accordion_area\">\n<div id=\"acc-prc\" class=\"box_accordion\">\n<div class=\"tit_accordion\">\n<div class=\"tit_accordion_box\">\n\t\t\t\t\tPreparing the remote controller\n\t\t\t\t<\/div>\n<div class=\"a_ico_box\"><span class=\"a_ico\"><\/span><\/div>\n<\/p><\/div>\n<div class=\"txt_accordion\">\n<div class=\"container accodion_wc\">\n<div class=\"att_accordion att_caution\">\n<div class=\"tit_att_accordion open\">\n<div class=\"tit_att_accordion_box\">\n\t\t\t\t\t\t\t\t<img src=\"https:\/\/web-manual.dit-daikin.com\/ra\/3P658678-5\/wp-content\/themes\/3rd_manual\/images\/common\/ico_att02.png\" alt=\"CAUTION\" \/>CAUTION\n\t\t\t\t\t\t\t<\/div>\n<div class=\"at_ico_box\"><span class=\"at_ico\"><\/span><\/div>\n<\/p><\/div>\n<div class=\"txt_att_accordion att_active\">\n<div class=\"case txt_b\">\n\t\t\t\t\t\t\t\tIncorrect handling of batteries can result in injury from battery leakage, rupturing or heating, or lead to equipment failure.\n\t\t\t\t\t\t\t<\/div>\n<h3 class=\"tit_bold\">Please observe the following precautions and use safely.<\/h3>\n<ul class=\"dot_li case\">\n<li>\n\t\t\t\t\t\t\t\t\tIf the alkaline solution from the batteries should get in the eyes, do not rub the eyes. Instead, immediately flush the eyes with tap water and seek the attention of a medical professional.\n\t\t\t\t\t\t\t\t<\/li>\n<li>\n\t\t\t\t\t\t\t\t\tKeep batteries out of the reach of children. In the event that batteries are swallowed, seek the immediate attention of a medical professional.\n\t\t\t\t\t\t\t\t<\/li>\n<li>\n\t\t\t\t\t\t\t\t\tDo not expose batteries to heat or fire. Do not disassemble or modify batteries. The insulation or gas release vent inside the battery may be damaged, resulting in battery leakage, rupturing, or heating.\n\t\t\t\t\t\t\t\t<\/li>\n<li>\n\t\t\t\t\t\t\t\t\tDo not damage or peel off labels on the batteries.\n\t\t\t\t\t\t\t\t<\/li>\n<\/ul><\/div>\n<\/p><\/div>\n<\/p><\/div>\n<div class=\"container\">\n<h3 class=\"tit_l_black\">To insert the batteries<\/h3>\n<ul class=\"num_li case\">\n<li>\n\t\t\t\t\t\t\tSlide the back cover to take it off.\n\t\t\t\t\t\t<\/li>\n<li>\n\t\t\t\t\t\t\tInsert 2 dry batteries AAA.LR03 (alkaline).\n\t\t\t\t\t\t<\/li>\n<li>\n\t\t\t\t\t\t\tReplace the back cover.<\/p>\n<div class=\"img_preparation01 txt_c\">\n\t\t\t\t\t\t\t\t<img src=\"https:\/\/web-manual.dit-daikin.com\/ra\/3P658678-5\/wp-content\/themes\/3rd_manual\/images\/before_operation\/img_preparation01_inv-low.gif\" alt=\"Replace the front cover.\" \/>\n\t\t\t\t\t\t\t<\/div>\n<\/li>\n<\/ul>\n<div class=\"case\">\n<div class=\"att_accordion att_note\">\n<div class=\"tit_att_accordion open\">\n<div class=\"tit_att_accordion_box\">\n\t\t\t\t\t\t\t\t\tNOTE\n\t\t\t\t\t\t\t\t<\/div>\n<div class=\"at_ico_box\"><span class=\"at_ico\"><\/span><\/div>\n<\/p><\/div>\n<div class=\"txt_att_accordion att_active\">\n<h3 class=\"tit_bold\">Notes on batteries<\/h3>\n<ul class=\"dot_li item\">\n<li>\n\t\t\t\t\t\t\t\t\t\tTo avoid possible injury or damage from battery leakage or rupturing, remove the batteries when not using the product for long periods of time.\n\t\t\t\t\t\t\t\t\t<\/li>\n<li>\n\t\t\t\t\t\t\t\t\t\tThe standard replacement time is 1 year. Both batteries should be replaced at the same time. Be sure to replace them with new size AAA. LR03 (alkaline) batteries.\n\t\t\t\t\t\t\t\t\t<\/li>\n<li>\n\t\t\t\t\t\t\t\t\t\tWhen battery power has run out, \u201c <img class=\"dis_battery_em\" src=\"https:\/\/web-manual.dit-daikin.com\/ra\/3P658678-5\/wp-content\/themes\/3rd_manual\/images\/common\/dis_battery_em.png\" alt=\"Batteries icon\" \/> \u201d will begin blinking as an alert that the batteries need replacing. In some cases, when battery consumption is accelerated owing to usage conditions, signal reception may decline before \u201c <img class=\"dis_battery_em\" src=\"https:\/\/web-manual.dit-daikin.com\/ra\/3P658678-5\/wp-content\/themes\/3rd_manual\/images\/common\/dis_battery_em.png\" alt=\"Batteries icon\" \/> \u201d begins blinking.\n\t\t\t\t\t\t\t\t\t<\/li>\n<li>\n\t\t\t\t\t\t\t\t\t\tThe batteries supplied with the remote controller are for initial operation. The batteries may run out in less than 1 year.<br \/>\n\t\t\t\t\t\t\t\t\t\tThe usable period of the batteries may be short depending on the manufacture date of the air conditioner.\n\t\t\t\t\t\t\t\t\t<\/li>\n<\/ul>\n<h3 class=\"tit_bold\">Notes on the remote controller<\/h3>\n<ul class=\"dot_li\">\n<li>\n\t\t\t\t\t\t\t\t\t\tDo not drop the remote controller. Do not get it wet.\n\t\t\t\t\t\t\t\t\t<\/li>\n<li>\n\t\t\t\t\t\t\t\t\t\tDust on the signal transmitter or receiver will reduce the sensitivity. Wipe off dust with a soft cloth.\n\t\t\t\t\t\t\t\t\t<\/li>\n<li>\n\t\t\t\t\t\t\t\t\t\tSignal communication may be disabled if an electronic-starter-type fluorescent lamp (such as an inverter-type lamp) is in the room.<br \/>\n\t\t\t\t\t\t\t\t\t\tConsult your dealer if that is the case.\n\t\t\t\t\t\t\t\t\t<\/li>\n<li>\n\t\t\t\t\t\t\t\t\t\tIf the remote controller signals happen to operate another appliance, move that appliance to somewhere else, or consult your dealer.\n\t\t\t\t\t\t\t\t\t<\/li>\n<\/ul><\/div>\n<\/p><\/div>\n<\/p><\/div>\n<\/p><\/div>\n<div class=\"btn_close\">Close<\/div>\n<\/p><\/div>\n<\/p><\/div>\n<div class=\"box_accordion\">\n<div class=\"tit_accordion\">\n<div class=\"tit_accordion_box\">\n\t\t\t\t\tPreparing the remote controller holder\n\t\t\t\t<\/div>\n<div class=\"a_ico_box\"><span class=\"a_ico\"><\/span><\/div>\n<\/p><\/div>\n<div class=\"txt_accordion\">\n<div class=\"container\">\n<h3 class=\"tit_l_black\">To fix the remote controller holder to a wall<\/h3>\n<ul class=\"num_li case\">\n<li>\n\t\t\t\t\t\t\tChoose a place from where the signals reach the unit.\n\t\t\t\t\t\t<\/li>\n<li>\n\t\t\t\t\t\t\tFix the holder to a wall, a pillar, or similar location with the screws supplied with the holder.\n\t\t\t\t\t\t<\/li>\n<li>\n\t\t\t\t\t\t\tPlace the remote controller in the remote controller holder.<\/p>\n<div class=\"img_preparation02 txt_c\">\n\t\t\t\t\t\t\t\t<img src=\"https:\/\/web-manual.dit-daikin.com\/ra\/3P658678-5\/wp-content\/themes\/3rd_manual\/images\/before_operation\/img_preparation02_inv-low.gif\" alt=\"Place the remote controller in the remote controller holder.\" \/>\n\t\t\t\t\t\t\t<\/div>\n<\/li>\n<\/ul><\/div>\n<div class=\"btn_close\">Close<\/div>\n<\/p><\/div>\n<\/p><\/div>\n<div class=\"box_accordion\">\n<div class=\"tit_accordion\">\n<div class=\"tit_accordion_box\">\n\t\t\t\t\tAttaching the small filters (Air quality filter (enzyme blue with PM2.5))\n\t\t\t\t<\/div>\n<div class=\"a_ico_box\"><span class=\"a_ico\"><\/span><\/div>\n<\/p><\/div>\n<div class=\"txt_accordion\">\n<div class=\"container\">\n<h3 class=\"tit_l_black\">Attach the Air quality filter (enzyme blue with PM2.5)<\/h3>\n<ul class=\"dot_li\">\n<li>\n\t\t\t\t\t\t\tIf attaching the separately sold filters, attach them before turning the power on.\n\t\t\t\t\t\t<\/li>\n<\/ul>\n<div class=\"btn_detail\">\n\t\t\t\t\t\t<a target=\"_blank\" href=\"..\/cleaning_filters\/#acc-filter02\" rel=\"noopener\">Details<\/a>\n\t\t\t\t\t<\/div>\n<\/p><\/div>\n<div class=\"btn_close\">Close<\/div>\n<\/p><\/div>\n<\/p><\/div>\n<div class=\"box_accordion\">\n<div class=\"tit_accordion\">\n<div class=\"tit_accordion_box\">\n\t\t\t\t\tTurning on the circuit breaker\n\t\t\t\t<\/div>\n<div class=\"a_ico_box\"><span class=\"a_ico\"><\/span><\/div>\n<\/p><\/div>\n<div class=\"txt_accordion\">\n<div class=\"container\">\n<h3 class=\"tit_l_black\">Turn on the circuit breaker<\/h3>\n<ul class=\"dot_li\">\n<li>\n\t\t\t\t\t\t\tAfter the power is turned on, the flaps of the indoor unit open and close once to set the reference position.\n\t\t\t\t\t\t<\/li>\n<\/ul><\/div>\n<div class=\"btn_close\">Close<\/div>\n<\/p><\/div>\n<\/p><\/div>\n<\/section>\n<\/div>\n","protected":false},"excerpt":{"rendered":"<p>Preparation before operation Preparing the remote controller CAUTION Incorrect handling of batteries can resul [&hellip;]<\/p>\n","protected":false},"author":1,"featured_media":0,"parent":203,"menu_order":0,"comment_status":"closed","ping_status":"closed","template":"page_read_before_operation.php","meta":[],"tags":[],"_links":{"self":[{"href":"https:\/\/web-manual.dit-daikin.com\/ra\/3P658678-5\/wp-json\/wp\/v2\/pages\/35"}],"collection":[{"href":"https:\/\/web-manual.dit-daikin.com\/ra\/3P658678-5\/wp-json\/wp\/v2\/pages"}],"about":[{"href":"https:\/\/web-manual.dit-daikin.com\/ra\/3P658678-5\/wp-json\/wp\/v2\/types\/page"}],"author":[{"embeddable":true,"href":"https:\/\/web-manual.dit-daikin.com\/ra\/3P658678-5\/wp-json\/wp\/v2\/users\/1"}],"replies":[{"embeddable":true,"href":"https:\/\/web-manual.dit-daikin.com\/ra\/3P658678-5\/wp-json\/wp\/v2\/comments?post=35"}],"version-history":[{"count":1,"href":"https:\/\/web-manual.dit-daikin.com\/ra\/3P658678-5\/wp-json\/wp\/v2\/pages\/35\/revisions"}],"predecessor-version":[{"id":601,"href":"https:\/\/web-manual.dit-daikin.com\/ra\/3P658678-5\/wp-json\/wp\/v2\/pages\/35\/revisions\/601"}],"up":[{"embeddable":true,"href":"https:\/\/web-manual.dit-daikin.com\/ra\/3P658678-5\/wp-json\/wp\/v2\/pages\/203"}],"wp:attachment":[{"href":"https:\/\/web-manual.dit-daikin.com\/ra\/3P658678-5\/wp-json\/wp\/v2\/media?parent=35"}],"wp:term":[{"taxonomy":"post_tag","embeddable":true,"href":"https:\/\/web-manual.dit-daikin.com\/ra\/3P658678-5\/wp-json\/wp\/v2\/tags?post=35"}],"curies":[{"name":"wp","href":"https:\/\/api.w.org\/{rel}","templated":true}]}}